SINOTIMER STVP-932 63A 3-phase 380V LCD Self-resetting Adjustable Surge Voltage Protector
SINOTIMER STVP-932 63A 3-phase 380V LCD Self-resetting Adjustable Surge Voltage Protector
Spread the cost
No lump sum. No stress. Pick a repayment term that works for your budget — and keep your cash flow intact.
- R367.18/mo 3 months
- R185.67/mo 6 months
- R97.99/mo 12 months
- R From R367.18/month over 3 months, or as low as R97.99/month over 12. Total repayable over 12 months: R1175.88. Interest at 20.75% p.a. applies.
- ✓ Quick online application — most people get a decision within minutes. Your first payment only kicks in 30 days after you buy.
- 🔒 Mobicred is a registered South African credit provider (NCR reg. NCRCP7852). Available to SA residents aged 18+ with a valid ID and bank account.
At checkout, simply select Mobicred as your payment method.
Continue to checkoutDon't have Mobicred yet? Apply free — takes about 2 minutes →
Mobicred is a revolving credit facility provided by Retail Capital (Pty) Ltd, a registered credit provider (NCR reg. NCRCP7852) in terms of the National Credit Act 34 of 2005. Credit is subject to approval and an affordability assessment. Interest rate: 20.75% p.a. compounded monthly (1.7292%/month). Available to South African residents aged 18 and older. Full terms & conditions apply.
Import Taxes Included
Read shipping & tax policy ›This product is priced for DDP import handling. KifTech handles applicable import costs before delivery:
- Import duties – Included where applicable
- Customs fees – Handled before delivery
- Shipping – Free on orders over R750. R49 standard rate below R750.
✓ The checkout total shows the product and shipping amount you pay to KifTech. No separate import duty payment should be required on delivery.
Free Shipping over R750
R49 below R750. Taxes included. Read policy ›
Estimated Arrival
8–17 business days after order placement.
Delivery Timeline
Order Processing (0–3 days)
Order verified and dispatched. Tracking details provided by email.
Transit (8–14 business days)
Package is shipped internationally to South Africa via Buffalo Logistics.
30-day refund / replacement
Read full return policy ›Shipping Protection
Read full policy ›Encrypted Checkout
Read privacy policy ›Checkout uses encrypted payment processing to help protect your personal and payment details.
Accepted via PayFast:
Product Overview
Features:
1. Overvoltage protection
2. Under voltage protection
3. Voltage display (voltage measurement ABC Separate Phase Voltage)
4. Three-phase voltage unbalance protection
5. Phase sequence protection (reverse phase protection)
6. Zero break protection
7. Phase failure protection
8. Overvoltage protection value is adjustable
9. Overvoltage recovery value is adjustable
10. Overvoltage protection action time is adjustable
11. Undervoltage protection value is adjustable
12. Undervoltage recovery value is adjustable
13. Undervoltage protection action time is adjustable
14. Three-phase voltage unbalance protection value is adjustable
15. Three-phase voltage unbalance protection action time is adjustable
16. The power-on delay time is adjustable
17. Fault recovery delay time is adjustable
18. Reset mode selection
19. Troubleshooting
20. Restore factory settings
Parameter:
1. Rated voltage: three-phase four-wire 230V/400VAC 50/60Hz
2. Rated current: 50A, 63A, 80A
3. Overvoltage protection value range: 221V-300V-OFF (default value 280V)
4. Overvoltage recovery value range: 220V-299V (default value 250V)
5. Overvoltage protection action time is adjustable: 0.1 seconds-10 seconds (default value 0.2 seconds)
6. Undervoltage protection value range: 219V-150V-OFF (default value 160V)
7. Undervoltage recovery value range: 220V-151V (default value 180V)
8. Undervoltage protection action time is adjustable: 0.1 seconds-10 seconds (default value 0.2 seconds)
9. Three-phase voltage unbalance protection value range: 10%-50%-OFF
10. Phase voltage unbalance protection action time: 0.1 seconds-10 seconds (default value 1.0 seconds)
11. Power-on delay connection time: 2-255 seconds (default value 2 seconds)
12. Failure recovery delay time: 2-512 seconds (default value 60 seconds)
13. Display mode: LCD
14. Fault indication: segment code characters
15. Sampling method: phase line to neutral line resistance divided voltage AC sampling
16. Grounding system: TT, TN-S, TN-C-S
17. Installation method: guide rail installation
18. Electrical isolation strength: greater than 2000VAC, pulse 2.5KV 1.2/50μS
19. Working environment: temperature -20-50 degrees Celsius, humidity less than 85% altitude: no more than 2000m
Product checks
Check fit before you buy
Review model, version, connector, size, photos, specifications, and package contents before checkout.
Compatibility checklist
- Match the exact product, device, model, size, colour, and variant shown in this listing.
- Brand names are used to identify compatibility unless the listing clearly states otherwise.
- For straps, cases, holders, covers, and accessories, check the size and compatible model before ordering.
- For powered products, check voltage, wattage, current, connector type, charger compatibility, and plug type before use.
Have questions about this product? Need help choosing? Contact our support team for assistance!
Share